What If Jiefang J6 Suddenly Can'T Catch Fire?
What If Jiefang J6 Suddenly Can’T Catch Fire?
2022-01-17
What Are The Misunderstandings Of Oil Tank Car Maintenance And How Much Do You Know?
What Are The Misunderstandings Of Oil Tank Car Maintenance And How Much Do You Know?
2022-01-19

Burning Tennac

There are thousands of roads, safety is the first. The tail gas does not meet the standard, and the driver tears. With the continuous development of society, everyone’s awareness of environmental protection is gradually strengthened. Under the situation of frequent introduction of environmental protection policies and national focus on environmental protection, diesel vehicles, as a major polluter, are the focus of motor vehicle emission control. If there are problems, they must be repaired in time.

Burning Tennac

Burning Tennac

Turner Online: "No" Urea Burning Tennac

Model: Jiefang “small J6”

Emissions: Country IV

Post treatment: tennac 1.5 generation

Fault phenomenon: emission is not up to standard

The owner reported that the vehicle had not added urea for nearly a year, and the exhaust gas did not meet the standard during the annual inspection. He requested that the urea system be repaired.

The car is equipped with “tennac” generation 1.5 urea system. The nozzle uses urea solution for heat dissipation, and the pump motor is a vulnerable part. When the motor is damaged, the urea pressure cannot be established, and the nozzle is damaged synchronously due to no urea heat dissipation.

Through C80 detection, the functional fault code of urea pressure sensor is read.

Start the engine and read the urea pressure data, which is always displayed as 0, and the urea pump cannot build pressure. Remove the B80 test on the connection between urea pump and nozzle, the motor does not run, and the pump motor needs to be replaced.

Replace with a new motor and test again. The pressure was successfully built up to 5.5bar. During the injection test, the nozzle did not act and was damaged. Replace the nozzle with a new one and test that the injection is normal.

Burning Tennac

Ensure that the urea system is clean, clean the urea tank and urea pipeline, reinstall the system, start the vehicle, the urea pressure always displays 0, no pressure is built, detect the circuit, measure a group of power supply on the pump, and find that the circuit is open circuit of the power line. After repair, check the urea pressure again. It is 2bar (standard nozzle heat dissipation pressure) at idle speed. Press the accelerator to the bottom to increase the exhaust temperature. When the exhaust temperature reaches 230 ℃, the urea pressure reaches 5.5bar (standard injection pressure).

Burning Tennac

Burning Tennac

Read that the system has no fault code and all data are normal. Let the customer pick up the car for use. Two days later, the customer came back and said that after driving more than 200 kilometers, the instrument showed that the urea level did not decrease, and there was no urea consumption.

The read historical fault code is urea nozzle line fault, and there is no current fault code. It is difficult to reproduce after the fault code is deleted. It is suspected that the nozzle line is faulty. The nozzle line “flies”, the nozzle plug is replaced, and the “three-way catalyst” is cleaned (try to meet the exhaust standard). The customer pays a return visit after one week of use, the urea consumption is normal, and the vehicle returns to normal

Turner Online: "No" Urea Burning Tennac

Summary:

1. When the Tenneco urea system is idling, the pump runs to establish a 2 bar urea pressure, which aims to dissipate heat to the urea nozzle and protect the nozzle from being damaged by the high temperature of exhaust.

2. When the exhaust temperature reaches about 230 ℃ during engine operation, the urea pressure rises to 5.5bar and is ready for injection.

3. When the exhaust temperature reaches above 300 ℃, urea is injected with the engine load (the speed is 1500 ~ 2000rpm / min). During detection, the sliding resistance simulation can be used to synchronously observe the exhaust temperature data, which is between 300 ~ 400 ℃.

4. When the liquid level is less than 20%, the urea lamp is on. It is required to add urea. When the liquid level is less than 10%, urea will not be injected. The urea solution will only circulate to ensure the heat dissipation of the nozzle.

Chat with us
Chat with us
Questions, doubts, issues? We're here to help you!
Connecting...
We are Sinotruksitrak. Please leave your inquiry and your phone. We will give you feedback within 12 hours.
Our operators are busy. Please try again later
:
:
:
:
Have you got question? Write to us! Please leave your phone or what'sApp
:
:
This chat session has ended