Maintenance Teacher Fu: There Are Seven Reasons For The High Water Temperature Of The Engine
Maintenance Teacher Fu: There Are Seven Reasons For The High Water Temperature Of The Engine
2022-01-16
Turner Online: "No" Urea Burning Tennac
Turner Online: “No” Urea Burning Tennac
2022-01-18

What's the reason why the car can't stop due to sudden failure?

Understanding the control logic of ECU and the correct use of detection equipment are very helpful for rapid maintenance. The following case is a failure caused by a small fault. Let’s understand the control logic of ECU on the starting system.

Model: FAW Jiefang J6

Engine: Xichai ca6dl2-35e3

Emission: Guosan

Computer board: Bosch edc7uc31

Jiefang J6 Suddenly

What If Jiefang J6 Suddenly Can'T Catch Fire?

Jiefang J6 Suddenly

Fault phenomenon: the headlight doesn’t light up and the heater doesn’t turn. After inspection, it is a white main line. The power line is broken and normal after repair; The starter doesn’t work in a taxi. It is suspected that the line repaired just now broke the starting line.

Troubleshooting steps:

1. Use a test lamp to measure that there is no power at the control end of the starting relay.

Jiefang J6 Suddenly

Fault analysis: according to the circuit diagram, when the starter is not working, there is no working voltage at the control terminal. When it needs to work, ECU controls the high-end output of 24V, forms a voltage difference between the high and low ends, and pulls in the relay. When starting the test, there are three possibilities that the test light does not light up.

1) Yes, the starting conditions are not met, and the ECU does not output the high-end control

2) The harness at the control end of the start relay is faulty.

3) ECU is damaged.

The vehicle starts normally when it comes, and the ECU damage may be very small. Give priority to checking the harness fault at the control end.

2. Check the harness. The harness is normal without short circuit and open circuit.

3. Check the neutral switch and forcibly start the key for ten seconds without response. Connect neutral switch signal line 1.85 and public high-end 1.04 together, and there is still no response when starting.

Jiefang J6 Suddenly

What If Jiefang J6 Suddenly Can'T Catch Fire?

4. Check T50 signal and disconnect ECU plug 1. Measure No. 1.61 with a test lamp, start the test, there is power, and T50 signal is normal.

5. Connect the two wires 1.37 and 1.51 at the control end of the starting relay to the starting relay. Connect the relay control end to the test lamp to start the test, and the test lamp is on.

Jiefang J6 Suddenly

Jiefang J6 Suddenly

6. Connect the start relay and there is no response at the start. The fault point is confirmed in the starting relay, and the fault is eliminated after replacing the relay.

Fault summary: why is there power at the end of the computer board and no power at the end of the relay?

Check that the control end of the relay is short circuited to the tower iron state. When ECU controls the operation of actuator, it will conduct self inspection on the status of actuator. When the line at the control end fails, a fault code will be reported, and the actuator will no longer be controlled. It is suggested that when the starting relay fails to supply power, the masters should open the relay circuit first and use the test lamp instead to detect the circuit.

Chat with us
Chat with us
Questions, doubts, issues? We're here to help you!
Connecting...
We are Sinotruksitrak. Please leave your inquiry and your phone. We will give you feedback within 12 hours.
Our operators are busy. Please try again later
:
:
:
:
Have you got question? Write to us! Please leave your phone or what'sApp
:
:
This chat session has ended