Technical Note: How Is Thrust Plate Related To Synchronization
Technical Note: How Is Thrust Plate Related To Synchronization
2021-12-19

Reading Guide: the teacher who often repairs the car knows that the accidental fault is the most difficult to check and the most annoying fault. Today, I received a faulty car. I accidentally took a taxi and the starter didn’t respond. Let’s have a look.

Lathe Maker Online: Occasional Non Start Fault Of Sinotruk T7h

Sinotruk T7h

Sinotruk T7h

Sinotruk T7h

Fault analysis of Sinotruk T7h

According to the historical fault analysis, the starter control circuit is open and the GPS is removed, which will cause no response to startup. Since the startup is normal when arriving at the site, the inspection may have definite results. First “remove the fault code” with the tester. After the system is normal, when the fault occurs again, read the fault code.

Exclusion steps of Sinotruk T7h

1. Repeated flameout and start-up tests showed that the starter did not respond. After reading the fault code, the tester displays “communication failure”. However, after power on again, the tester’s communication returns to normal and the code reading system is normal. At this time, it can also be started normally.

2. After repeated tests, it is observed that when a fault occurs, the communication failure of ECU is accompanied.

3. It is suspected that the ECU is not powered on when it cannot be started. After a fault occurs, disconnect the rail pressure sensor and measure the voltage. The measured voltage of 5v5v0v is normal, and it is ruled out that the ECU is powered on

4. Observe and start relevant data flow and find that T50 signal is always closed. However, the maintenance department has replaced the key door and checked the T50 signal line before.

5. Find the K35 wire key, turn it to the start gear, measure the voltage and find that there is no voltage. Quickly eliminate the fault, directly pull 24V from the positive pole of the battery to K35, and the signal state of data flow T50 becomes “on”, but the start relay does not pull in at this time.

6. It is suspected that the vehicle starter relay is not controlled by ECU. Measure that the two wires at the starter control end are connected with k71 and k29.

Thus, the starting logic of the vehicle is determined, and the starting relay is controlled by ECU. However, T50 signal is no longer received by hard wire, and key door T50 is not connected to ECU. According to the vehicle with nano BCU, query the data T50 signal to the body computer and send it to the ECU through the can line.

7. With CAN bus analysis function, there is no engine module when it cannot be started.

Lathe Maker Online: Occasional Non Start Fault Of Sinotruk T7h
Lathe Maker Online: Occasional Non Start Fault Of Sinotruk T7h

Sinotruk T7h

Sinotruk T7h

Fault summary of Sinotruk T7h

Lathe Maker Online: Occasional Non Start Fault Of Sinotruk T7h
Chat with us
Chat with us
Questions, doubts, issues? We're here to help you!
Connecting...
We are Sinotruksitrak. Please leave your inquiry and your phone. We will give you feedback within 12 hours.
Our operators are busy. Please try again later
:
:
:
:
Have you got question? Write to us! Please leave your phone or what'sApp
:
:
This chat session has ended