Every data stream, every fault code and every fault phenomenon are telling their own “story”. This
story needs people to understand, listen and interpret. Of course, it needs people to repair it; In this
issue, xiaorail will interpret a strange “story” for you.
Use a diagnostic expert to read the fault code
The display system is normal without fault code. At the same time, observe that the water in oil fault lamp
on the instrument panel is on.
If there is water in the oil fault, it may lead to engine weakness; Next, detect the water content fault in the oil.
Check water in oil sensor
It is found that the water in oil sensor contains a lot of water. Drain the water in the sensor, power on
and off the key, and the water in oil fault light goes out.
Go out for test run
Let the master go out for test run and read the driving data stream at the same time.
From the data stream, no exception is found; At the same time, the driver reported that the fault
of water in the oil often occurs recently, and suspected whether there was a problem with the oil.
Check the fuel tank
It can be seen from the figure that the fuel has changed color. It can be inferred that it is caused
by the coolant entering the fuel tank.
The position that will cause coolant to enter the fuel tank is generally the copper sleeve of fuel
injector, the connection between cylinder block oil passage and coolant passage.
Disassemble the engine
Disassemble the engine and remove the copper sleeve of fuel injector. It is found that six copper sleeves
are corroded, and the copper sleeves of cylinder 1 and cylinder 2 are cracked; Copper sleeve corrosion is
the main cause of coolant entering the fuel tank. During disassembly, I smelled peculiar smell in the
coolant. It is suspected that the coolant has deteriorated, resulting in corrosion of the copper sleeve.
Replace the coolant and injector copper sleeve
Clean the fuel tank after replacement.
After completion, let the driver out of the sports car and the fault is removed.
After the vehicle has been running for one month, the power is insufficient again and the
water in the oil fault light is on. Use a diagnostic expert to read the fault code and data flow.
The situation is the same as the last time. Check the fuel tank and find that the coolant enters
the fuel tank again. When disassembling the engine, the copper sleeve of fuel injector is corroded.
The situation is exactly the same as last time.
The small rail is also the first time to see this kind of fault of repeated corrosion of the copper sleeve of
the fuel injector. I have no direction here.
When I put the cooling water, I seem to smell urea. Is urea in the cooling water? There is only one place
where urea enters the coolant, that is, the urea tank. Next, check the urea tank and check the urea level sensor.
Check urea level sensor
It was found that the urea level sensor had cracks, resulting in the mixing of coolant and urea solution,
so that part of urea solution entered the cooling water channel.
When coolant enters the urea tank, it will dilute urea. At this time, faults exceeding 5 and 7 may be
reported, but this time the fault is not reported. Asked the driver if the car burns urea. The driver said
that the car has not burned urea. The urea solution has not been added for a long time, but the power
has not been affected, indicating that the after-treatment of the car has been shielded.
Replace the urea level sensor with a new one
After replacing the sensor, clean the urea tank and fuel tank and let the driver go out of the sports car
again. The fault did not reappear and the fault was repaired.
Many masters must be confused when it comes to the fault case. What is the relationship between
the leakage of the liquid level sensor of the urea tank and the corrosion of the copper sleeve?
Before talking about this, we need to understand that copper can react with urea solution (ammonia).
At high temperature, it will aggravate the reaction between urea (NH3) and copper (Cu). The specific
reaction equation is as follows:
In other words, the ammonia entering the coolant reacts with the copper sleeve at high temperature,
resulting in the corrosion of the copper sleeve of the fuel injector. Therefore, this is the cause of the fault.
The liquid level sensor is damaged, resulting in urea entering the coolant. The urea entering the coolant
corrodes the copper sleeve of the fuel injector. The copper sleeve of the fuel injector is damaged, resulting
in coolant entering the fuel tank. The water in the fuel tank leads to insufficient engine power.
Here is another hidden problem that I want to talk to you about; In this case, the liquid level sensor is
damaged, the urea enters the coolant, and the coolant also enters the urea tank. The coolant dilutes the
urea. Under normal circumstances, it will report more than five and more than seven faults. However,
in this case, it is not reported because the vehicle brushes the data processed after the screen, resulting in
no relevant faults, It prolongs our time to solve the problem.
If the system is normal, the troubleshooting will be relatively simple. For many shielded data, urea will
not build pressure and report fault codes, but the heating function is not shielded, that is to say, the cooling
water valve of urea tank will still open, resulting in urea entering the coolant.
The hot summer is coming. In this issue of knowledge development, I will explain the knowledge related to air
conditioning to you.
System and component composition
The structure of air conditioner consists of compressor, condenser, evaporator, expansion valve, sight
glass, drying bottle, etc.
1.1 compressor
The function of the compressor is to compress the low-pressure refrigerant gas into high-pressure refrigerant
gas.
1.2 condenser
The function of condenser is to convert high-temperature and high-pressure gas refrigerant into
high-temperature and high-pressure liquid, and release heat to the atmosphere to achieve the
purpose of heat exchange.
1.3 evaporator
The function of evaporator is to convert the low-temperature and low-pressure gas-liquid mixed
refrigerant into low-temperature and low-pressure gas, and absorb the heat in the gas at the same time.
1.4 expansion valve
Expansion valve is an important part of refrigeration system, which is generally installed between
liquid reservoir and evaporator. The expansion valve throttles the medium temperature and high
pressure liquid refrigerant into low temperature and low pressure wet steam, and then the refrigerant
absorbs heat in the evaporator to achieve the refrigeration effect.
Function of thermal expansion valve:
1) After passing through the throttling valve, the refrigerant with high temperature and low pressure will
become liquid refrigerant and expand into throttled flow under the action of throttling valve;
2) Control the refrigerant flow: the expansion valve controls the refrigerant flow to ensure that the outlet of
the evaporator is completely gaseous refrigerant. If the flow is too large, the outlet contains liquid refrigerant,
which may enter the compressor and produce liquid hammer; If the refrigerant flow is too small, the
evaporation is completed in advance, resulting in insufficient refrigeration.
1.5 refrigerant
Also known as refrigerant, it is commonly known as snow species in some areas of the south. It is a working
substance that circulates continuously in the refrigeration system and realizes refrigeration through its own
state change. The refrigerant vaporizes by absorbing the heat of the cooling medium (water or air) in the
evaporator, and condenses by transferring the heat to the surrounding air or water in the condenser.
R-134a (1,1,1,2-tetrafluoroethane) is a refrigerant that does not contain chlorine atoms, does not damage
the ozone layer and has good safety performance (non flammable, non explosive, non-toxic, non irritating
and non corrosive). Its refrigeration capacity and efficiency are very close to R-12 (dichlorodifluoromethane,
Freon).
1.6 lubricating oil
R134a is an integral part of the air conditioning lubrication system. PAG lubricating oil is mixed with R134a and
circulated in the air conditioning system.
be careful:
1) Do not turn on the air conditioner without refrigerant, because no lubricating oil will cause damage to the
compressor and other internal components.
2) In the use of air conditioner, only the specified lubricating oil shall be used. For example, a swashplate
compressor uses SP-20 PAG oil.
3) Do not splash PAG lubricating oil on the skin. Rinse immediately with water.
4) Do not breathe in the mixture of PAG lubricating oil and R134a.
5) PAG lubricating oil is easy to volatilize. Open the jar only when in use and screw on the lid immediately after use.
2.1 compression process
The low-temperature and low-pressure refrigerant gas absorbed by the evaporator is sucked by the compressor
and then adiabatically compressed into high-temperature and high-pressure gas, which is sent to the condenser.
2.2 condensation process
After the refrigerant gas with high temperature and high pressure enters the condenser, it exchanges heat with the
ambient air and becomes a liquid with high temperature and high pressure.
2.3 throttling process
After the high-pressure refrigerant liquid is discharged by the condenser, it is dried and filtered by the liquid reservoir,
throttled and depressurized by the expansion valve, and becomes a low-temperature and low-pressure liquid gas
mixture into the evaporator.
2.4 evaporation process
The throttled low-temperature and low-pressure refrigerant is gasified after entering the evaporator to absorb the
heat in the vehicle and become low-temperature and low-pressure steam. At the same time, the temperature in
the vehicle is reduced.
The Fuel Injector,
The Fuel Injector,
SITRAK, HOWO, HOHAN, STEYR, WANGPAI, FOLOR, and becomes China’s truck manufacturer with the most complete drive types and power range in heavy-duty truck industry.